Governor Model Data for Power System Transient Stability Studies

Governor Model Data for Power System Transient Stability Studies

Governor System Data

Identify appropriate IEEE model block diagram of governor system for computer representation in power system stability simulations and the corresponding governor system constants for use in the model.

Data sheets for common standard turbine-governor models presented in alphabetical order.

Turbine-Governor Models
GAST Gas turbine-governor model
GAST2A Gas turbine-governor model
GASTWD Gas turbine-governor model
IEEEG1 1981 IEEE type 1 turbine-governor model
IEEEG2 1981 IEEE type 2 turbine-governor model
IEEEG3 1981 IEEE type 3 turbine-governor model
IEESGO 1973 IEEE standard turbine-governor model
TGOV1 Steam turbine-governor model
TGOV2 Steam turbine-governor model with fast valving
WESGOV Westinghouse digital governor for gas turbine

Gas Turbine Model – GAST2A

Woodward Governor Gas Turbine Model – GASTWD

*Temperature control output is set to output of speed governor when temperature control input changes from positive to negative.

IEEE Type 1 Speed-Governing Model – IEEEG1

IEEE Type 2 Speed-Governing Model – IEEEG2

IEEE Type 3 Speed-Governing Model – IEEEG3

IEEE Standard Governor – IEESGO

Steam Turbine-Governor – TGOV1


Steam Turbine-Governor with Fast Valving – TGOV2

 

Westinghouse Digital Governor for Gas Turbine – WESGOV