This article is about Hazardous Gas Analyzer Installation, as example of Rosemount Analyzer.
Hazardous Gas Analyzer Installation
manual-x-stream-short-form-manual-5th-ed-rosemount-en-71926Following is short explanation of which topics are mentioned in this article.
- Overview
- Housings
- The Front Panel / User Interface
- Interfaces
- Comparison of the Various X-STREAM Analyzer Models
- X-STREAM X2GK: ½ 19 Inch Table-Top Unit
- X-STREAM X2GP: 19 Inch Table-Top or Rackmount Design
- X-STREAM X2XF: Field Housing With Single (XLF) or Dual (XXF) Compartment
- X2XF Field Housings for Installation in Hazardous Areas (Ex-Zones)
- Measurement Specifications
Hazardous Gas Analyzer Installation
- Scope of Supply
- Introduction
- Technical Data
- Common Technical Data
- Specific Technical Data .
- Gas Conditioning
- Gas Connections
- Electrical Connections
- Detailed Instructions for Installation
- X-STREAM X2GK, X-STREAM X2GP
- X-STREAM X2XF
- Notes On Wiring Signal Inputs and Outputs .
- Electrical Shielding of Cables
- Wiring Inductive Loads
- Driving High-Current Loads
- Driving Multiple Loads
Hazardous Gas Analyzer Startup
- Performing a Leak Test
- The User Interface .
- Display
- Status LED
- Keys
- Symbols Used
- Software
- Navigating and Editing
- Access Levels
- Special Messages
- Powering Up
- Boot Sequence
- Measurement Display
- Selecting the Language
- Checking the Settings
- Installed Options .
- Configuring the Display
- Calibration Setup
- Setting the Analog Outputs
- Setting Concentration Alarms
- Backing Up the Settings
Hazardous Gas Analyzer Maintenance
- Perform a Calibration .
- Preparing Calibrations
- Manual Calibration
Chapter 5 Dismounting and Disposal
-
- Dismounting and Diposal of the Analyzer .
- Block Diagram
- Assignment of Terminals and Sockets
- Tabletop & Rack Mount Analyzers
- Field Housings
There are following figures explained in this document above attached for hazardous gas analyzer installation of rosemount,.
- Figure: X-STREAM Front Panel (here the X-STREAM X2GP
- Figure: X-STREAM X2GK
- Figure: X-STREAM X2GP – Details
- Figure: X-STREAM XLF / XXF- Front Views
- Figure: X-STREAM XLF – Side and Bottom View
- Figure: X-STREAM XLF – Power Supply and Signal Terminals
- Figure: X-STREAM X2 Analyzers – Scope of Supply
- Figure: Labelling of Gas Connectors (example)
- Figure: Installation in Bypass Mode
- Figure: X-STREAM X2GK – Rear Panel
- Figure: X-STREAM X2GP – Rear Panel, Shown With Options
- Figure: X-STREAM X2GK & X2GP – Dimensions
- Figure: Socket X1 – Analog Outputs & Digital Outputs 1-4
- Figure: Power Supply Connectors
- Figure: X-STREAM XLF – Dimensions for Installation
- Figure: X-STREAM XXF – Dimensions for Installation
- Figure: X-STREAM X2XF Field Housing – Terminals, Cable Glands, Gas Connectors .
- Figure: Terminal Block X1 – Analog Outputs & Digital Outputs 1-4 (XSTA)
- Figure: Power Supply Connections
- Figure: Shielded Signal Cable, Shielding Connected At Both Ends.
- Figure: Shielded Signal Cable, Shielding Connected At One end.
- Figure: Signal Cable With Double Shielding, Shieldings Connected At Alternate Ends. .Fig. 2-17: Shield Connector Terminal With Cable
- Figure: Suppressor Diode for Inductive Loads.
- Figure: Driving High-Current Loads
- Figure: Loads in Series
- Figure: Loads in Parallel
- Figure: Leak Testing With U-Turn Manometer
- Figure: X-STREAM Front Panel
- Figure: Limits Defining a Window for Valid Concentrations
- Figure: High Pre-Alarm and Main Alarm
- Figure: Low Pre-Alarm and Main Alarm
- Table: Gas Components and Measuring Ranges, Example
- Table: IR, UV, VIS, TCD – Measurement Performance Specifications
- Table: Oxygen – Standard Measurement Performance Specifications
- Table: Trace Moisture – Standard Measurement Performance Specifications
- Table: Special Performance Specifications for Gas Purity Measurements
- Table: Analog Output Signals: Settings and Operational Modes
- Table: Analog Outputs – Scaling (examples)
- Table: Influence of “SpanRange” Parameter on Concentration Alarm Limits ……….