Hazardous Gas Analyzer Installation

This article is about Hazardous Gas Analyzer Installation, as example of Rosemount Analyzer.

Hazardous Gas Analyzer Installation

manual-x-stream-short-form-manual-5th-ed-rosemount-en-71926

Following is short explanation of which topics are mentioned in this article.

  1. Overview
  2. Housings
  3. The Front Panel / User Interface
  4. Interfaces
  5. Comparison of the Various X-STREAM Analyzer Models
  6. X-STREAM X2GK: ½ 19 Inch Table-Top Unit
  7. X-STREAM X2GP: 19 Inch Table-Top or Rackmount Design
  8. X-STREAM X2XF: Field Housing With Single (XLF) or Dual (XXF) Compartment
  9. X2XF Field Housings for Installation in Hazardous Areas (Ex-Zones)
  10. Measurement Specifications

Hazardous Gas Analyzer Installation

  1.  Scope of Supply
  2. Introduction
  3. Technical Data
    1. Common Technical Data
    2. Specific Technical Data .
  4. Gas Conditioning
  5. Gas Connections
  6. Electrical Connections
  7. Detailed Instructions for Installation
    1. X-STREAM X2GK, X-STREAM X2GP
    2. X-STREAM X2XF
  8. Notes On Wiring Signal Inputs and Outputs .
    1. Electrical Shielding of Cables
    2. Wiring Inductive Loads
    3. Driving High-Current Loads
    4. Driving Multiple Loads

Hazardous Gas Analyzer Startup

  1. Performing a Leak Test
  2. The User Interface .
    1. Display
    2. Status LED
    3. Keys
  3. Symbols Used
  4. Software
    1. Navigating and Editing
    2. Access Levels
    3. Special Messages
  5. Powering Up
    1. Boot Sequence
    2. Measurement Display
  6. Selecting the Language
  7. Checking the Settings
    1. Installed Options .
    2. Configuring the Display
    3. Calibration Setup
    4. Setting the Analog Outputs
    5. Setting Concentration Alarms
    6. Backing Up the Settings

Hazardous Gas Analyzer Maintenance

  1. Perform a Calibration .
    1. Preparing Calibrations
    2. Manual Calibration

Chapter 5 Dismounting and Disposal

    1. Dismounting and Diposal of the Analyzer .
  1. Block Diagram
  2. Assignment of Terminals and Sockets
    1. Tabletop & Rack Mount Analyzers
    2. Field Housings

There are following figures explained in this document above attached for hazardous gas analyzer installation of rosemount,.

  • Figure: X-STREAM Front Panel (here the X-STREAM X2GP
  • Figure: X-STREAM X2GK
  • Figure: X-STREAM X2GP – Details
  • Figure: X-STREAM XLF / XXF- Front Views
  • Figure: X-STREAM XLF – Side and Bottom View
  • Figure: X-STREAM XLF – Power Supply and Signal Terminals
  • Figure: X-STREAM X2 Analyzers – Scope of Supply
  • Figure: Labelling of Gas Connectors (example)
  • Figure: Installation in Bypass Mode
  • Figure: X-STREAM X2GK – Rear Panel
  • Figure: X-STREAM X2GP – Rear Panel, Shown With Options
  • Figure: X-STREAM X2GK & X2GP – Dimensions
  • Figure: Socket X1 – Analog Outputs & Digital Outputs 1-4
  • Figure: Power Supply Connectors
  • Figure: X-STREAM XLF – Dimensions for Installation
  • Figure: X-STREAM XXF – Dimensions for Installation
  • Figure: X-STREAM X2XF Field Housing – Terminals, Cable Glands, Gas Connectors .
  • Figure: Terminal Block X1 – Analog Outputs & Digital Outputs 1-4 (XSTA)
  • Figure: Power Supply Connections
  • Figure: Shielded Signal Cable, Shielding Connected At Both Ends.
  • Figure: Shielded Signal Cable, Shielding Connected At One end.
  • Figure: Signal Cable With Double Shielding, Shieldings Connected At Alternate Ends. .Fig. 2-17: Shield Connector Terminal With Cable
  • Figure: Suppressor Diode for Inductive Loads.
  • Figure: Driving High-Current Loads
  • Figure: Loads in Series
  • Figure: Loads in Parallel
  • Figure: Leak Testing With U-Turn Manometer
  • Figure: X-STREAM Front Panel
  • Figure: Limits Defining a Window for Valid Concentrations
  • Figure: High Pre-Alarm and Main Alarm
  • Figure: Low Pre-Alarm and Main Alarm
  • Table: Gas Components and Measuring Ranges, Example
  • Table: IR, UV, VIS, TCD – Measurement Performance Specifications
  • Table: Oxygen – Standard Measurement Performance Specifications
  • Table: Trace Moisture – Standard Measurement Performance Specifications
  • Table: Special Performance Specifications for Gas Purity Measurements
  • Table: Analog Output Signals: Settings and Operational Modes
  • Table: Analog Outputs – Scaling (examples)
  • Table: Influence of “SpanRange” Parameter on Concentration Alarm Limits ……….