This article is about Architectural Inspector Checklists Part 1- Aramco Cbt Exam Questions related to topic of Waterproofing, Insulation, Rigid Insulation, Reflective Insulation, Loose Fill Insulation, Shingles & Roofing Tiles , Wood Shingles & Shakes, Asphalt Shingles, Slate Shingles, Concrete & Clay Tile, Membrane Roofing, Flashing & Sheet Metal, Gutters, Downspouts, Base & Cap Flashing, Other Roof Flashing, Wall Flashing, Cementitious Fireproofing in Building, Plants and Petrochemical Plants as per International Codes & Standards.

Architectural Inspector Checklists Part 1- Aramco Cbt Exam Questions related to topic of Waterproofing, Insulation, Rigid Insulation, Reflective Insulation, Loose Fill Insulation, Shingles & Roofing Tiles , Wood Shingles & Shakes, Asphalt Shingles, Slate Shingles, Concrete & Clay Tile, Membrane Roofing, Flashing & Sheet Metal, Gutters, Downspouts, Base & Cap Flashing, Other Roof Flashing, Wall Flashing, Cementitious Fireproofing

Architectural Inspector Checklists Part 1- Aramco Cbt Exam Questions

ARCHITECTURAL INSPECTOR CHECKLISTS PART 1- ARAMCO CBT EXAM QUESTIONS

WATERPROOFING

The place required by contract paperwork or warranties, confirm that waterproofing is put in by producer’s accredited installers. Earlier than waterproofing or dampproofing subcontractor is allowed to start work, see that:

INSULATION

Confirm supplies are of kind required (surfaces, therapy, rankings, sizes, thickness, and many others.)

RIGID INSULATION

Confirm wooden nailers/stops are offered, as required. Guarantee vapor barrier is offered, if required. Verify that vapor barrier seals insulation at gravel stops, partitions, and openings.

REFLECTIVE INSULATION

Confirm batt insulation is of sufficient width to suit between framing members and is of specified thickness or “R” worth.

LOOSE FILL INSULATION

Confirm there is no such thing as a settlement. Confirm there aren’t any voids.

SHINGLES & ROOFING TILES

Confirm delivered supplies are of grades, varieties, shapes, sizes, colours, fire-rated classification and sample texture required, as relevant.

WOOD SHINGLES & SHAKES

Confirm underlayment, the place required, is offered and put in with correct lapping shingle model. Confirm publicity and fastening is as required, format present full shingle programs and general alignment is managed. Evaluate sample is indicated.

ASPHALT SHINGLES

Confirm underlayment or membrane is offered, if required. Confirm slope is as required. If roof surfaces don’t have adequate slope, contact architect earlier than set up of roofing begins.

SLATE SHINGLES

See objects above the place relevant.

CONCRETE & CLAY TILE

Confirm underlayment, the place required, is offered and put in with correct lapping shingle model.

MEMBRANE ROOFING

Confirm supplies of varieties required are offered. Confirm softening level of bitumen is as required. Confirm supplies are identifiable and adjust to ASTM or FS requirements. Confirm roll roofing is stood on finish and saved freed from contact with earth or moisture. Confirm protecting coverings of saved roll roofing is vented so condensation is not going to happen.

FLASHING & SHEET METAL

Confirm delivered materials is of accredited kind, form, gauge, metallic, fabrication and priming, as required, and all equipment are offered.

DOWNSPOUTS

Confirm lengths are so long as sensible and in accordance with specs. Confirm slip joints in course of circulation or allowance for motion is offered.

BASE & CAP FLASHING

Confirm flashing is offered to swimsuit situations: cant, dimension, gauge, and fabrication.

WALL FLASHING

Confirm places for flashings fabrication and design with contractor. Confirm lap, flip up, location in wall, depth in masonry, size, and many others. are as required.

CEMENTITIOUS FIREPROOFING

Confirm set up is by a agency accredited by the sprayed fireproofing materials producer.  Confirm fireproofing offers fireresistance rankings as examined by acceptable laboratories. Confirm producersinformation and directions for correct utility of sprayed fireproofing are on file.